Project Description

DC Contactor-EVQ300

EVQ300

300A electromagnetic DC contactor, DC 12-900V, contactor coil voltage 12V/24V, 48V/72V

High voltage DC contactor, normally open (SPST-NO), 300 amps rated load current, available with 12V/24V, 47/72V coils.
It’s widely used as EV contactor, main contactor in charging station, EV, HEV, photovoltaic, energy storage, AGV, UPS, etc.

  • Epoxy sealed.
  • Magnetic arc blowout.
  • Compact design, low noise.
  • Build-in energy saving board
  • Bi-directional, optional with polarized or non-polarized contact.
  • Optional auxiliary contact.
  • CE, CCC and RoHS compliant.
Enquiry

EVQ Series Contactors can switch DC loads at both low and high voltage from 12 to 900VDC. These hermetically sealed contactors can be mounted in any position, can be used in nearly any harsh environment at temperatures from –40°C to 85°C. They are the preferred contactor (sometimes called a relay ) for electric vehicles, hybrid vehicles,heavy trucks and equipment, busses, emergency vehicles, boats, LRT, mining,  power management systems for battery charging, fuel cells, battery backup, photovoltaic, wind and wave power systems where long life and high reliability are needed.All EVQ Series contactors meet RoHS and CE,CCC Conformance requirements.

Parameters
Contact arrangementSPST-NO
Main contact ParameterRated load voltage (Ue)12-900Vdc
Rated load current1-300A
Max continuous themal current400A 1200sec
600A 180sec
Max.switching current 1 time only2000A 320Vdc
General DataInitial contact resistance1mΩ Max.(at 1A)
operate time(at 20℃)25ms Max.
Bounce time(at 20℃)7ms Max.
Release time(at 20℃)12ms Max.
Electricity lifeWith polarityDC450V,2x103times
DC750V,1x103times
Without polarityDC450V,2x103times
DC750V,1x103times
Mechanical Life2×105
InsulationInsulation resistanceInitial:100MΩ Min.
Life End: 50MΩ Min.
Dielectric strengthcoil to contactAC 2500 Vrms/1mA/1min.(At sea level)
contact to contactAC 2500 Vrms/1mA/1min.(At sea level)
Mechanical functionShock resistance20Gpeak value,11ms 1/2sinusoid(coil power setup)
Vibration resistance20Gpeak value,80~2,000Hz,sinusoid
Coil parameterNominal voltage12-36Vdc48-72Vdc
Coil Power (W)Start current:3.8A
Retentive power: 2W
Start current:1.3A
Retentive power: 2W
Coil polarity
Auxiliary contact option
Mounting & ConnectionsM8 Male thread/M6 Female thread
Environmental parameterAmbient Temperature-40~+85℃
Relative Humidity5~95% RH.
Dimension80.5x65.2x72mm
Weight ( g )430±10g

    Contact Hotson Team!