Project Description

EVQ600
600 amp contactor high current, DC 12-900V, contactor coil voltage 12V-36V
EVQ600
600 amp contactor high current, DC 12-900V, contactor coil voltage 12V-36V
High voltage DC contactor, normally open (SPST-NO), 600 amps rated load current, available with 12V-36V coils. It’s specially designed for high current DC switching application, offer high continuous current up to 600A.
It’s widely used as EV contactor, main contactor in charging station, main contactor in EV, HEV, photovoltaic/ Solar system, energy storage, AGV, UPS, etc.
- Epoxy sealed.
- Magnetic arc blowout.
- Compact design, low noise.
- Build-in energy saving board
- Optional auxiliary contact.
- CE, CCC and RoHS compliant.
EVQ Series Contactors can switch DC loads at both low and high voltage from 12 to 900VDC. These hermetically sealed contactors can be mounted in any position, can be used in nearly any harsh environment at temperatures from –40°C to 85°C. They are the preferred contactor (sometimes called a relay ) for electric vehicles, hybrid vehicles,heavy trucks and equipment, busses, emergency vehicles, boats, LRT, mining, power management systems for battery charging, fuel cells, battery backup, photovoltaic, wind and wave power systems where long life and high reliability are needed.All EVQ Series contactors meet RoHS and CE,CCC Conformance requirements.
Parameters | |||
---|---|---|---|
Contact arrangement | SPST-NO | ||
Main contact Parameter | Rated load voltage (Ue) | 12-900Vdc | |
Rated load current | 1-600A | ||
Max continuous themal current | 700A 600sec | ||
1500A 20sec | |||
Max.switching current 1 time only | 2500A 320Vdc | ||
General Data | Initial contact resistance | 0.2mΩ Max.(at 600A) | |
operate time(at 20℃) | 40ms Max. | ||
Bounce time(at 20℃) | 5ms Max. | ||
Release time(at 20℃) | 20ms Max. | ||
Electricity life | With polarity | DC450V,6x103times DC750V,3x102times | |
Without polarity | -- | ||
Mechanical Life | 2×105 | ||
Insulation | Insulation resistance | Initial:100MΩ Min. | |
Life End: 50MΩ Min. | |||
Dielectric strength | coil to contact | AC 2500 Vrms/1mA/1min.(At sea level) | |
contact to contact | AC 2500 Vrms/1mA/1min.(At sea level) | ||
Mechanical function | Shock resistance | 20Gpeak value,11ms 1/2sinusoid(coil power setup) | |
Vibration resistance | 20Gpeak value,80~2,000Hz,sinusoid | ||
Coil parameter | Nominal voltage | 12-36Vdc | |
Coil Power (W) | Start current:2.32A Retentive power: 2W | ||
Coil polarity | √ | ||
Auxiliary contact option | √ | ||
Mounting & Connections | M10 Male screw thread | ||
Environmental parameter | Ambient Temperature | -40~+85℃ | |
Relative Humidity | 5~95% RH. | ||
Dimension | 78.1x66.6x103mm | ||
Weight ( g ) | 930±10g |